An operator can hit the wrong well, skip a column or double-dispense, and nothing in the instrument knows.
"Nothing tracks the location of the pipette when aspirating and/or dispensing liquid."
Kobra's patented vision system photographs the pipette tip at the instant it aspirates or dispenses, checks the well against the protocol, and blocks the transfer if it is wrong. We license it to liquid-handling and lab-automation manufacturers.
| Time | Op | Well | Target µL | Actual µL | Result |
|---|
The gap
Manual and electronic pipettes leave no trace of where liquid came from or where it went. Volume calibration drifts as seals wear. Regulated labs fill that gap with paper sign-offs. Kobra's invention fills it with images, positions and timestamps.
An operator can hit the wrong well, skip a column or double-dispense, and nothing in the instrument knows.
"Nothing tracks the location of the pipette when aspirating and/or dispensing liquid."
Motor-step volume estimates fall out of calibration as internal seals wear, so reported volumes lose reliability over time.
"Manual pipette performance cannot be accepted without monitoring and reporting."
Forensic, clinical-trial and IVD results are challenged on chain of custody. Operator-entered logs are weak evidence.
"Standardize processes and document every liquid transfer with quality and defensible data."
How the system works
The pipette's buttons are wired to the vision system. Pressing one triggers image capture, the controller locates the tip, and liquid moves only when the location matches the step in the recipe.
Labware sits on fixed locators at known positions relative to the cameras. The system reads barcodes on plates, racks and tip boxes and checks the layout against the selected recipe.
Actuating aspirate, dispense, mix or tip-eject fires the cameras. The image is taken at the moment of transfer, not before or after it.
Two or more cameras, or a stereoscopic pair, triangulate the 3D position of the pipette over the deck. A second pass resolves the tip inside a specific well, helped by a high-contrast UV or color ring on the tip.
The controller compares tip position and requested function against the protocol. A wrong well or wrong function is blocked before liquid moves, and the operator is warned on the pipette and the monitor.
Source and destination wells, target and measured volume, tip lot, operator, image and timestamp go into an auditable record for each transfer.
Claim map
Each independent claim covers a fluid-sample validation system made of a hand-grippable pipette, one or more target locations, and at least one camera viewing those locations. They differ in how the camera, controller and protocol work together.
The pipette's actuator buttons are coupled to the camera, so pressing a button to aspirate or dispense also acquires an image of the target.
A controller holds the protocol as a series of steps and inhibits the aspirator/dispenser when a function outside the protocol is attempted. The pipette signals each attempt, and the controller allows or blocks it based on tip location seen by the camera.
Multiple target locations at known positions; cameras acquire time-stamped images verifying tip location and function; several cameras combine to confirm position; and a multi-tip pipette whose tip spacing matches the target spacing transfers along a line of wells at once.
The claim 9 arrangement of known target positions, time-stamped verification images and a multi-tip pipette with matched spacing, without requiring a plurality of cameras.
Plain-language summaries for orientation only. The issued claims of US 10,809,275 B2 define the scope of protection. CPC classes include G01N 35/1016, B01L 3/021, G06K 9/00771 and G06T 7/0012.
For lab robotics manufacturers
The claims center on connected handheld pipettes verified by cameras. The specification also describes robotized pipettes, teach-by-demonstration and metered licensing. Each item below is marked by where it appears in the patent.
Extend an automation platform to the manual bench with the same deck definitions, labware library and audit trail, so semi-automated labs can stay in your ecosystem.
Block a transfer before liquid moves, not after a failed QC. Wrong well, wrong function and wrong source are stopped at the controller.
Stereoscopic cameras resolve position and orientation of 8-tip and 2D tip heads, so a whole column or row is verified in one capture.
The specification describes robotizing the pipette, with the cameras still confirming that each aspirate, dispense, mix and tip change happened at the right location.
An operator performs a method once by hand in teach mode. The recorded positions and volumes become a recipe that a robotic arm can replay or other stations can enforce.
A serial-number key enables the system and can generate a billing event per session, with a demo mode for training. That supports recurring revenue for an instrument maker.
Reference implementation
Kobra built the patented system as a working bench instrument: a sensor-controlled handheld pipette, a camera and lighting tower over a locator deck, and a controller that drives aspiration and records results.
Engineering depth
Kobra's team comes from life-science automation. Our instrument software stack is layered so verification can sit on top of a licensee's own motion control, tools and deck definitions.
Physical devices: motors, I/O and barcode imagers, with low-level details hidden behind a common API.
IAxisIGPIOIBCReaderReadManyWithMappingDetectObjectRobotic architecture: how elements connect, home, move in real-world units and avoid collisions.
ISlideIRotaryICarriageIZAxisIToolEnd effectors built on ITool, including pipettors with independent volume, independent Z, spreadable tips and liquid detection.
PlateGripperTubeGripperPipettorDispenserThe real-world workspace the verification layer checks against.
WorkspaceLiquidClassLabwareGeometryPipettorTipsDemand
The patent names forensic, clinical, pharmaceutical, hospital and biotech labs. These are the buyers your instruments already serve, and the ones under the most pressure to prove each transfer.
Barcode-scanned blood tubes tracked from rack to plate with an image of each transfer, for crime labs that must defend results in court.
Plasma, tissue and liquid-biopsy transfers documented for regulatory submissions and CRO process validation.
Every manual pipetting step monitored and reported, removing operator technique as a source of error.
Plate replication, serial dilution and 96-well workflows with multichannel position and volume validation.
Licensing
Terms are set per partner. These are the starting structures we discuss with manufacturers.
Exclusive rights within a defined application such as forensics, clinical diagnostics or genomics.
Rights to practice the patent across your liquid-handling and bench products.
A license combined with Kobra's instrument design, application and software services.